SANYO’s
MIR series of Cooled Incubators are recognized as exceptional laboratory
incubators specifically designed for a wide range of incubation and test
applications. Try this Cooled Incubator for your Drosophila incubation,
BOD testing or for crystallography. The MIR-254 and 554 cooled
incubators could suit your crystallography applications since the
refrigeration system can be isolated from the incubator chassis to
reduce vibration.
Cooled Incubator - Temperature and programming
Each
model of MIR cooled Incubator has a wide temperature range from -100C
to +600C. MIR Cooled Incubators can be operated at a single
user-defined temperature and can also be programmed with up to 12
different temperature stems with lighting being programmed as either on
or off using the optional lighting kit. These Cooled Incubators also
feature a programmed memory backup system. Should the power source be
interrupted due to power failure or other event, programmed data remains
stored in the memory. When the power source is restored, operation can
be continued according to the predetermined program.
Your experiment therefore resumes under the same predetermined program
even when interrupted by a temporary lack of power from the power
source.
Cooled Incubator - Reduces culture media drying out
When
using “vented” culture vessels / culture plates, the new range of
MIR Cooled Incubators reduce the amount the cultures dry out because of
the new fan circulation design. The MIR 154 and 254 feature the new
oblique fan design which in conjunction with the new air plenum design
reduces the airflow across the samples. Thus reducing the amount
cultures could dry out, whilst still maintaining good temperature
distribution throughout the incubation chamber.
The
incubators incorporate an extensive temperature prevention circuit that
protects experimentation materials in the rare event that a temperature
abnormality may occur. This system turns off the heater and chamber fan
motor when too high a temperature is detected. The compressor is also
turned off when too low a temperature is detected.
Cooled Incubator - Features
The New MIR-154, 254 and 554 Cooled Incubators feature
the following (further information is available by downloading the
product literature at the foot of this page):
- A
New LCD Controller with 12 steps, 10 programs.
- P.I.D
Temperature Control of the heaters
- Temperature
selection from -10C to +60C
- On-
Board data storage (previous 2 weeks).
- Single
Lamp Chamber Lighting.
- Programmable
4 lamp Chamber Lighting as an optional kit.
- Design
reduces the level of media drying.
- Tamper-proof
Controls
- Automatic
setting Temperature Alarms
- Stackable
(MIR-154 only).